Level Finish · Technical Test Report
Omega P800 vs Kovax K-800: different removal, essentially equal finish
Level Finish Omega P800 refining disc vs Kovax / Eagle Super Assilex Lemon K-800. One controlled comparison on a clear-coated test panel, run by dry hand sanding under a defined 40-pass cycle, with 24 stock-removal locations measured per product. Under that cycle, the two discs behaved differently: the Lemon K-800 removed more material on average, while the surface each one left behind measured essentially the same. Both results are published here, including the one that favors Kovax, because at P800 the cut and the finish are two separate questions.

What happened, in short
- Material removal: Lemon K-800 removed more. Mean removal was 0.2004 for Lemon K-800 vs 0.1700 for Omega, a difference of 0.0304. That is approximately 17.9% more for Lemon relative to Omega, or, stated the other way, Omega averaged approximately 15.2% less removal relative to Lemon.
- Surface finish: essentially equivalent. Mean post-sanding Ra was 0.3190 µm for Omega vs 0.3200 µm for Lemon K-800, a difference of 0.0010 µm (0.31%). The test record states that a difference this small has no established practical significance without repeatability or measurement-uncertainty evidence.
- Matched locations: mixed. Omega recorded the lower Ra at 2 of 5 matched sampling locations, Lemon K-800 at 2 of 5, and the two were equal at 1.
- The honest summary: different removal, essentially the same measured finish, and no overall winner established by this test.
Method
Both products were tested by dry hand sanding on one clear-coated panel, by the same operator, at 40 passes per product, using a soft interface to help manage pressure. The panel is a grid of columns A to L and rows 1 to 8, in 2 by 2 inch squares. Lemon K-800 was tested in area A1:C8 and Omega in area J1:L8, with stock removal measured at 24 locations per product. The two product systems are built differently: Omega is hook-and-loop backed and the Lemon sheet is felt and loop backed, and each product ran with the interface arrangement appropriate to it, so the physical systems were not identical. Calculated removal is the post-sanding reading minus the baseline reading at each matched location; negative results were assigned 0.00 and zero values were retained in every summary. Post-sanding surface roughness was recorded as Ra (arithmetic average surface roughness, in µm; lower is finer), sampled at rows 1, 2, 4, 5, and 7. The starting panel included P2000-sanded areas and compounded, refined areas, and starting gloss was not identical across all areas.

Results: material removal
| Material removal | Kovax / Eagle Lemon K-800 | Level Finish Omega P800 |
|---|---|---|
| Mean removal | 0.2004 | 0.1700 |
| Median removal | 0.1950 | 0.1850 |
| Minimum removal | 0.000 | 0.000 |
| Maximum removal | 0.370 | 0.250 |
| Sample standard deviation | 0.0685 | 0.0713 |
| Sum of 24 readings | 4.81 | 4.08 |

Lemon K-800 averaged 0.0304 more removal than Omega under the same 40 passes. Removal alone does not establish which product suits a given job; that depends on how much correction the stage calls for, as the finish results below show.
Results: surface finish
| Post-sanding Ra | Kovax / Eagle Lemon K-800 | Level Finish Omega P800 |
|---|---|---|
| Mean Ra | 0.3200 µm | 0.3190 µm |
| Absolute difference | 0.0010 µm lower | |
| Relative difference | 0.31% lower | |
| Matched locations where Ra was lower | 2 of 5 | 2 of 5, with 1 equal |
| Sample row | Omega P800 Ra | Lemon K-800 Ra | Difference (Lemon minus Omega) |
|---|---|---|---|
| 1 | 0.331 µm | 0.408 µm | +0.077 µm |
| 2 | 0.303 µm | 0.308 µm | +0.005 µm |
| 4 | 0.341 µm | 0.297 µm | -0.044 µm |
| 5 | 0.293 µm | 0.293 µm | 0.000 µm |
| 7 | 0.327 µm | 0.294 µm | -0.033 µm |

A positive difference means Lemon read rougher at that row; a negative difference means Omega read rougher. The rows split both ways, and the averages landed 0.0010 µm apart. On finish, this test is a tie in every practical sense.
Microscopy
The microscopy in the test record is reported observation; the original microscope images were not supplied with the report, so the observations are published here as reported. Unused, the Omega surface appeared uniform and light gray or beige, with fine distributed contrast, while the Lemon surface appeared strongly textured, with reflective, angular-looking clusters. After 40 passes, both abrasives showed a broader blue and cyan appearance with their original features less distinct, the change was reported across the supplied fields, and no obvious catastrophic disruption was reported for either product. On the sanded clear coat, both products produced predominantly directional scratch patterns, and isolated prominent lines occurred in both. Because the two abrasives began from visibly different microscopic baselines, the size of the visual change is not a direct measure of comparative wear. Microscopy does not independently quantify abrasive wear percentage, mineral loss percentage, loading composition, or remaining abrasive life, so none of those figures appear on this page.

How to read this test
P800 is a finer preparation step, and the two discs offer a genuine trade-off under this test: Lemon K-800 corrected more material per the defined pass count, while Omega removed less and left the same average measured finish. Which behavior suits the job depends on defect severity, how much clear coat you want to conserve, and what the next refinement step needs. The test record establishes no overall winner, and neither does this page. Note that this is the Omega P800 comparison against Kovax / Eagle Lemon K-800, by hand sanding. It is a different test from the Alpha P800 comparison against 3M Cubitron II, which has its own page.
More test results
Omega P600 vs Kovax Sky K-600, the companion test on the same panel: see the Omega P600 test results. Omega P2000 vs 3M Purple P2000, filmed side by side on one panel: see the filmed test results. Alpha P800 vs 3M Cubitron II, a different product and a different test: see the Alpha P800 test results. More reports are filed here as testing is completed.
Notes and limitations
Each comparison is a single controlled trial under its documented conditions, and the results describe that trial. The source reports do not state a unit for the stock-removal values, so no unit is stated here. Starting gloss was not identical across all areas of the test panel. The 0.31% average Ra difference has no established practical significance without repeatability or measurement-uncertainty evidence. Ra is the measured arithmetic average surface roughness under the documented test conditions; it is not a measurement of individual scratch width or depth. Results from one grit or substrate do not transfer to another.
Frequently asked questions
Did the Kovax K-800 remove more than Omega P800?
Yes. Mean calculated removal was 0.2004 for Lemon K-800 vs 0.1700 for Omega, approximately 17.9% more relative to Omega. Stated the other way, Omega averaged approximately 15.2% less removal relative to Lemon.
Did Omega P800 leave a finer finish?
No. Mean post-sanding Ra was 0.3190 µm for Omega vs 0.3200 µm for Lemon K-800, a difference of 0.0010 µm, and the matched locations split 2 for Omega, 2 for Lemon, and 1 equal. The finishes measured essentially equivalent.
So which disc won?
Neither, on this record. The two products behaved differently on removal and the same on average finish, and the test record establishes no overall winner. The choice depends on whether the stage calls for more correction or more conservation.
Is this the same test as the Alpha P800 page?
No. This page is Omega P800 vs Kovax / Eagle Lemon K-800, tested by hand sanding. The Alpha P800 page is Alpha vs 3M Cubitron II, a different product and a different opponent, with its own results.
Level Finish · St. George, Utah · level-finish.com · Source: Level Finish verified comparative test record and the full P800 vs K-800 and combined 600 and 800 test reports supplied November 14, 2026. All numbers transcribed exactly from those records; no values added or altered.